Description
|
When selecting this system to use with other M-Series indoor units it is adviced to keep the indoor unit ratings within the kW/Btu rating of the outdoor unit.
i.e- if you choose a MXZ-5A100VA Condensing unit (3.4 kW / 14.3 kW) then you would be able to use units within th 14.3 kW range. You would be able to run 5 x 3.5kw in any combination of indoor unit.
|
| The Mitsubishi Electric air conditioning Multi-Split System allows multiples of Mr Slim or M Series indoor units to be operated from a single outdoor unit. This makes it an economic answer in multi-room applications, whilst also offering space saving benefits. The indoor units are the M series which are renound for quiet operation and outstanding reliablity. A compact design makes these units ideal for commercial and home air conditioning applications. |
Key product Feature's:
- Multiple indoor units connected to a single outdoor unit
- Single outdoor unit for minimal noise and space impact
- Energy saving inverter controlled performance
- Compact design indoor and outdoor
- Mixture of differant types of indoor unit's if required
- New design indoor unit
- High COP 3.75
- Infra-red controller with wall mounting bracket
- Auto re-start after power interruption
- PRE-CHARGED WITH REFRIGERANT for
up to 20 metres pipe length
- Fault diagnosis
- New advanced technology control
Outdoor Units:
|
| MXZ-2A52VA |
Allows 2 indoor unit to be connected
|
|
| Capacity (kW): |
|
| Heating (Nominal) (Low - High) |
6.4 (1.0 - 7.2) |
| Cooling (Nominal) (Low - High) |
5.2 (1.1 - 6.0) |
| Heating (UK) (Low - High) |
5.3 (0.85 - 6.0) |
| Cooling (UK) (Low - High) |
5.15 (1.1 - 5.95) |
| COP / EER (Nominal) |
3.75 / 3.46 |
| Energy Label Heating / Cooling |
A / A |
| Maximum Number of Connectable Indoor Units |
2 |
| Width - mm |
800 |
| Depth - mm |
285 |
| Height - mm |
550 |
| Weight - kg |
40 |
| Airflow (m3/min) (Heating / Cooling) |
31 / 31 |
| Noise (dBA) (Heating / Cooling) - Lo-Hi |
48-50 / 45-49 |
| Electrical Supply |
220-240v, 50Hz |
| Phase |
Single |
| Fuse Rating (BS88) - HRC (A) |
16 |
| Interconnecting Cable No. Cores |
4 |
| Power Input (kW) - Heating (Nominal) |
1.705 |
| Power Input (kW) - Cooling (Nominal) |
1.505 |
| Power Input (kW) - Heating (UK) |
1.55 |
| Power Input (kW) - Cooling (UK) |
1.2 |
| Starting Current (A) |
7.64 |
| Running Current (A) - Heating / Cooling |
7.64 / 6.75 |
| Mains Cable No. Cores |
3 |
| Charge R410A (kg) - 20m |
1.3 |
| Total Pipe Length (m) |
30 |
| Max Pipe Length per Indoor Unit (m) |
20 |
| Indoor to Outdoor Height (m) |
15 |
| MXZ-3A54VA |
Allows 3 indoor unit to be connected |
| Heating (Nominal) (Low - High) |
6.8 (2.6 - 9.0) |
| Cooling (Nominal) (Low - High) |
5.4 (2.9 - 6.8) |
| Heating (UK) (Low - High) |
5.65 (2.15 - 7.5) |
| Cooling (UK) (Low - High) |
5.35 (2.9 - 6.75) |
| COP / EER (Nominal) |
4.67 / 4.17 |
| Energy Label Heating / Cooling |
A / A |
| Maximum Number of Connectable Indoor Units |
3 |
| Width - mm |
870 |
| Depth - mm |
330 |
| Height - mm |
710 |
| Weight - kg |
57 |
| Airflow (m3/min) (Heating / Cooling) |
41.2 / 42.1 |
| Noise (dBA) (Heating / Cooling) - Lo-Hi |
47-48 / 44-46 |
| Electrical Supply |
220-240v, 50Hz |
| Phase |
Single |
| Fuse Rating (BS88) - HRC (A) |
16 |
| Interconnecting Cable No. Cores |
4 |
| Power Input (kW) - Heating (Nominal) |
1.455 |
| Power Input (kW) - Cooling (Nominal) |
1.295 |
| Power Input (kW) - Heating (UK) |
1.32 |
| Power Input (kW) - Cooling (UK) |
1.04 |
| Starting Current (A) |
6.39 |
| Running Current (A) - Heating / Cooling |
6.39 / 5.69 |
| Mains Cable No. Cores |
3 |
| Charge R410A (kg) - 40m |
2.7 |
Piping Restrictions
| Total Pipe Length (m) |
50 |
| Max Pipe Length per Indoor Unit (m) |
25 |
|
Indoor to Outdoor Height (m)
|
15
|
| MXZ-4A80VA |
Allows 4 indoor unit to be connected |
|
| Capacity (kW): |
|
| Heating (Nominal) (Low - High) |
9.40 (3.40 - 11.60) |
| Cooling (Nominal) (Low - High) |
8.00 (3.70 - 9.20) |
| Heating (UK) (Low - High) |
7.80 (2.85 - 9.65) |
| Cooling (UK) (Low - High) |
7.95 (3.65 - 9.15) |
| COP / EER (Nominal) |
4.87 / 3.65 |
| Energy Label Heating / Cooling |
A / A |
| Maximum Number of Connectable Indoor Units |
4 |
| Width - mm |
900 |
| Depth - mm |
355 |
| Height - mm |
900 |
| Weight - kg |
70 |
| Airflow (m3/min) (Heating / Cooling) |
43.8 / 42.2 |
| Noise (dBA) (Heating / Cooling) - Lo-Hi |
46-48 / 44-46 |
| Electrical Supply |
220-240v, 50Hz |
| Phase |
Single |
| Fuse Rating (BS88) - HRC (A) |
25 |
| Interconnecting Cable No. Cores |
4 |
| Power Input (kW) - Heating (Nominal) |
1.93 |
| Power Input (kW) - Cooling (Nominal) |
2.19 |
| Power Input (kW) - Heating (UK) |
1.76 |
| Power Input (kW) - Cooling (UK) |
1.75 |
| Starting Current (A) |
9.62 |
| Running Current (A) - Heating / Cooling |
8.48 / 9.62 |
| Mains Cable No. Cores |
3 |
| Charge R410A (kg) - 40m |
3.5 |
| Total Pipe Length (m) |
70 |
| Max Pipe Length per Indoor Unit (m) |
25 |
| Indoor to Outdoor Height (m) |
15 |
| MXZ-5A100VA |
Allows 5 indoor unit to be connected |
|
| Capacity (kW): |
|
| Heating (Nominal) (Low - High) |
12.0 (3.4 - 14.0) |
| Cooling (Nominal) (Low - High) |
10.0 (3.7 - 11.0) |
| Heating (UK) (Low - High) |
9.95 (2.85 - 11.65) |
| Cooling (UK) (Low - High) |
9.9 (3.65 - 10.9) |
| COP / EER (Nominal) |
4.23 / 3.41 |
| Energy Label Heating / Cooling |
A / A |
| Maximum Number of Connectable Indoor Units |
5 |
| Width - mm |
900 |
| Depth - mm |
320 |
| Height - mm |
900 |
| Weight - kg |
68 |
| Airflow (m3/min) (Heating / Cooling) |
59.3 / 56.6 |
| Noise (dBA) (Heating / Cooling) - Lo-Hi |
46-54 / 45-51 |
| Electrical Supply |
220-240v, 50Hz |
| Phase |
Single |
| Fuse Rating (BS88) - HRC (A) |
25 |
| Interconnecting Cable No. Cores |
4 |
| Power Input (kW) - Heating (Nominal) |
2.835 |
| Power Input (kW) - Cooling (Nominal) |
2.935 |
| Power Input (kW) - Heating (UK) |
2.58 |
| Power Input (kW) - Cooling (UK) |
2.35 |
| Starting Current (A) |
12.88 |
| Running Current (A) - Heating / Cooling |
12.45 / 12.88 |
| Mains Cable No. Cores |
3 |
| Charge R410A (kg) - 40m |
4 |
| Total Pipe Length (m) |
80 |
| Max Pipe Length per Indoor Unit (m) |
25 |
| Indoor to Outdoor Height (m) |
15 |