Description
13.3kW / 44000 Btu Heatpump Inverter Split Type Cassette Air conditioning System.
|
Cassette Heat Pumps for Commercial & Residential Applications. Ideal for large open plan areas, or irregular shaped rooms.
|
|
Efficient distribution of air
In order to be able to adapt to the shape of the room to be conditioned, the Fujitsu cassette units are
able to configure the air impulsion in two, three or four different directions and thus achieve uniform air
conditioning.
Air flow direction and auto swing
The unit can make a sweep using its deflector slats to air-condition the premises more quickly. The direction of the sweep as well as the auto swing function can be selected by using the remote control.
Weekly programming control
Models with a movable rosette incorporate weekly programming control that allows on and of f programming up to twice a day.
Functions:
- Programming of different operating schedules each day.
- On and off programming twice a day.
- Set the time in periods of five minutes.
- Cancellation of operation on a specific day (public holiday)
|
Product Key Feature's
• CoP 3.02
• Energy saving inverter
• Advanced technology control
• Hard wired controller
• Slim construction
• Pipe runs up to 70 metres
• Noise – 36dBA
• Back-up switch for loss of controller
• Cold draft prevention on heat pump start up
• Fault diagnosis
• Auto re-start after power interruption
• PRE-CHARGED WITH REFRIGERANT for
up to 20 metres pipe length

Technical Data
|
Cooling capacity kcal/
|
11438 (5504-12470)
|
|
W
|
13300 (6400-14500)
|
|
Heating capacity kcal/
|
13760 (5848-14190)
|
|
W
|
16000 (6800-16500)
|
|
Energy efficiency ratio (E.E.R.)
|
2.44
|
|
Heating
|
3.23
|
|
Power supply v/n /Hz
|
230/1/50
|
|
Power consumption (Cooling/Heating) kW
|
5.45/4.95
|
|
Starting current A
|
15
|
|
Running current (cooling/heating) A
|
23.8/21.6
|
|
Electrical wiring
|
(O.U) 2x4+T
|
|
Electrical connection
|
3x1,5+T
|
|
Noise level unit high dB (A)
|
51
|
|
Medium dB (A)
|
49
|
|
Low dB (A)
|
46
|
|
Noise level outdoor unit dB (A)
|
54
|
|
Dimensions indoor unit Width mm
|
830 (940)
|
|
Depth mm
|
830 (940)
|
|
Height mm
|
296 (30)/250
|
|
Dimensions outdoor unit Width mm
|
900
|
|
Depth mm
|
330
|
|
Height mm
|
1290
|
|
Net weight (Indoor/Outdoor)
|
40/105
|
|
Pipe size Inch.
|
3/8” – 5/8”
|
|
Pipe length max. (Total/Height) m
|
70/30
|
|
Refrigerent Type
|
R410A
|
|
Refridgerant charge m
|
20
|
|
Operating range cooling ºC
|
-15/+43
|
|
Heating ºC
|
-15/+24
|